NEW: Carrier TCED12A2A5-0A0G0 10 ton Gas Package 410a

  • $7,500.00
  • Save $2,495
Shipping calculated at checkout.


Carrier 10 ton Gas Package unit, 410a Refrigerant- Model TCED12A2A5-0A0G0

Description

48TCDD12A2A5-0A0G0
48 = Gas Heat Packaged Rooftop
TC = WeatherMaker™ Standard Efficiency
D = Low Heat
D = Two Stage Cooling Models 08-16
12 = 10 tons
A = None
2 = Belt Drive, Medium Static Option
A = Al/Cu - Al/Cu
5 = 208-230/3/60
0 = Electromechanical Controls can be used with W7212 EconoMi$er IV (Non-Fault Detection and Diagnostic)
A = None
0 = None
G = 2-Speed Indoor Fan (VFD) Controller
0 = Standard
* Contact your Carrier expert for additional information.

* Actual item may vary from stock photo

The Carrier rooftop unit (RTU) was designed by customers for customers. With “no-strip screw” collars, handled access panels, and more we’ve made your unit easy to install, easy to maintain and easy to use.
Easy to install:
All WeatherMaker® units are field-convertible to horizontal air flow which makes it easy to adjust to unexpected job site complications. Lighter units make easy replacement. Most Carrier 48TC rooftops fit on existing Carrier curbs dating back to 1989. Also, our large control box gives you room to work and room to mount Carrier accessory controls.
Easy to maintain:
Easy access handles by Carrier provide quick and easy access to all normally serviced components. Our “no-strip” screw system has superior holding power and guides screws into position while preventing the screw from stripping the unit’s metal. Take accurate pressure readings by reading condenser pressure with panels on. Simply remove the black, composite plug, route your gauge line(s) through the hole, and connect them to the refrigeration service valve(s).
Easy to use:
The newly designed, central terminal board by Carrier puts all your connections and troubleshooting points in one convenient place, standard. Most low voltage connections are made to the same board and make it easy to find what you’re looking for and easy to access it. Carrier rooftops have high and low pressure switches, a filter drier, and 2-in (51mm) filters standard.

FEATURES AND BENEFITS
  • Single cooling stage models are available from 3 - 10 ton.
  • Two cooling stage models are available from 7.5 - 15 ton.
  • SEER up to 13.0 (up to 13.4 with ECM motor)
  • EER’s up to 11.1 (up to 11.4 with ECM motor)
  • IEER’s up to 11.8 with single speed indoor fan motor and up to 12.8 with 2-speed/VFD indoor fan motor.
  • Up to 28% lighter than similar industry units. Lighter rooftops make easier replacement jobs.
  • Utility connections are the same because 3 - 12.5 ton units fit on existing Carrier rooftop curbs. This saves time and money on replacement jobs.
  • Standardized components and layout. Standardized components and controls make service and stocking parts easier.
  • Scroll compressors on all units. This makes service, stocking parts, replacement, and troubleshooting easier.
  • Field convertible airflow (3 - 15 ton). Being able to convert a unit from vertical airflow to horizontal makes it easy to overcome job site complications. 15 ton models require a simple supply duct cover to field convert from factory vertical to horizontal.
  • Easy-adjust, belt-drive motor available.
  • Provisions for bottom or side condensate drain.
  • Capable of thru-the-base or thru-the-curb gas line routing.
  • Single-point gas / electrical connection.
  • Sloped, composite drain pan sheds water; and won’t rust.
  • Standardized controls & control box layout. Standardized components & controls make stocking parts & service easier.
  • Tool-less filter access door.
  • Clean, large, easy to use control box.
  • Color-coded wiring.
  • Large, laminated wiring and power wiring drawings which are affixed to unit make troubleshooting easy.
  • Single, central terminal board for test and wiring connections.
  • Fast-access, handled, panels for easy access on normally accessed service panels.
  • “No-strip” screw system guides screws into the panel & captures them tightly without stripping the screw, the panel, or the unit.
  • Mechanical cooling (115°F to 40°F or 46°C to 4°C) standard on all models. Winter Start Kit allows cooling operation down to 25°F (-4°C) and MotorMaster to -20°F (-29°C).
  • High efficiency, gas heat with induced-draft flue exhaust design.
  • Induced draft motor ensures no flue gas can escape into the indoor air stream.
  • Carrier designed naturally draining heat exchanger, unlike positive pressure heat exchangers, do not need to be periodically, manually drained. This saves labor and maintenance expense.
  • 2-in (51mm) disposable filters on all units.
  • Refrigerant filter-drier on each circuit.
  • Each circuit is protected with a high and low pressure switch.
  • Many factory-installed options ranging from air management economizers, 2 position dampers, plus convenience outlets, disconnect switches and smoke detectors.
  • Standard (parts only) Warranty: 10 yr. aluminized heat exchanger, 5 yr. compressor, 3 yr. Novation condenser coil, 1 yr. parts.
  • Factory-installed Humidi-MiZer® adaptive dehumidification system on all sizes with round tube / plate fin condenser coils, includes MotorMaster I controller.
  • NOTE: The last order date for 48TC 04-06 units with Humidi-MiZer is October, 12, 2015. Use KC, HC or LC models after the last order date.
  • Optional Staged Air Volume (SAV) system utilizes a Variable Frequency Drive (VFD) to automatically adjust the indoor fan motor speed between cooling stages. Available on 2-stage cooling models 08-16 with electromechanical controls or RTU Open.

Specifications

Weight 940 Pounds (lbs)
Length 88.125 Inches (In)
Width 59.5 Inches (In)
Height 49.375 Inches (In)
Country of Origin Var
Air Flow Convertible
Blower Motor HP 3 7/10 BHP
Blower Motor RPM 838-1084
Blower Motor Speeds 2 (Two)
Blower Motor Type Fixed Torque
Blower Wheel 15" x 15"
Brand Carrier
Certifications AHRI Certified
Circuit Breaker - Max Amps 60
Circuit Breaker - Min Amps 48.5
Color Gray
Compressor Scroll
Condenser Motor HP 1/4 HP
Condenser Motor RPM 1100
Condenser Motor Type Direct Drive
Cooling Capacity 114000
Cycle/Hertz 60 Hz
Drain Connection Size 3/4"
Drive Type Belt
EER 11.1
Energy Star Rated No
ETL Listed Yes
Filter Size (4) 20" x 20" x 2" RA filter, (1) 20" x 24" x 1" OA filter
Heating Capacity 98000-148000
IEER 12.8
Locked Rotor Amps 110
Phase Three
Product Family 48TC
Prop 65 Yes
Rated Load Amps 15.6,15.9
Refrigerant R-410a
Sound Level (dBA) 82
Stage Two
Thermal Efficiency 82%
Tonnage 10
UL Listed Yes
Voltage 208-230 VAC